Table 1 Summary of the results at different energies.

Measured fringe period d3, contrast C, and peak contrast position Y0, as discussed in the text.

E (keV)d3 (μm)C (%)Y0 (mm)
165.853 ± 0.001stat ± 0.050syst45.8 ± 1.5−2.9 ± 0.6
145.851 ± 0.001stat ± 0.050syst49.1 ± 0.5−2.3 ± 0.6
115.852 ± 0.001stat ± 0.050syst43.6 ± 0.8−2.2 ± 0.6
95.852 ± 0.001stat ± 0.050syst26.7 ± 0.8−2.3 ± 0.6
85.850 ± 0.001stat ± 0.050syst14.4 ± 0.8−2.2 ± 0.6